ENIGMA
SHOWER ECLOSURE INSTALLATION INSTRUCTIONS
IMPORTANT
DreamLine
TM
reserves the right to alter, modify or redesign products at any time without
prior notice. For the latest up-to-date technical drawings, manuals or any other details
please refer to the support.BathAuthority.com web page.
60” wide 72” wide
Please read these instructions carefully before installing. If you have any questions
regarding installation, please call our technical support specialists Monday through Friday
9:00 AM – 5:00 PM EST at Phone: 1-866-731-2244, Fax: 1-866-227-1533 or e-mail our
technical support group at
support@BathAuthority.com.
For more information on DreamLine
TM
Shower Enclosures please visit www.BathAuthority.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - 60” wide 72” wide

ENIGMA SHOWER ECLOSURE INSTALLATION INSTRUCTIONS IMPORTANT DreamLineTM reserves the right to alter, modify or redesign products at any time wit

Strona 2 - Tools Required

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 10 10. Mark the drilling holes on the floor through the predrilled holes in the Threshold (15). Remove t

Strona 3 - Packing List B

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 11If the width of your door is 72” and you are installing the door with the Small Stationary glass (24),

Strona 4 - Shower Enclosure Plan

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 12 13. Make sure the Stationary glass (02) and the Guide rail (03) are leveled. If a horizontal adjustme

Strona 5 - Fig. 1

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 13 15. Apply a small amount of silicone into the Threshold (15) channel. Place the Stationary glass (02)

Strona 6

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 14 ATTENTION: This Step shows Small Stationary Glass (24) installation for 72” door only. 16. Screw of

Strona 7

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 15 17. A. Measure the distance between the Stationary glass (02) and the Return panel (22) for 60” door

Strona 8 - Fig. 8

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 16 19. Attach two top Rollers (04) to the Glass door (05). Suspend the door by hanging the Rollers onto

Strona 9 - Fig. 10

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 17 21. Press the Bumper strip (13) on the vertical edge of the Glass door (05) and also press the Anti

Strona 10

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 18 23. Apply silicone along the connection of the Stationary glasses to the wall. You may also apply add

Strona 11 - Fig. 14

DREAMLINE™EXCLUSIVELIMITEDWARRANTYASOFMAY6,2013Thiswarrantyextendsonlytotheoriginalowner/end‐userforhouseholduseonlyandis nott

Strona 12 - Fig. 16

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 2Preparation 1. After opening all boxes and packages, read this introduction carefully. Check that all

Strona 13 - Fig. 18

TEL: 866-731-2244 FAX: 866-227-1533 WWW.BATHAUTHORITY.COM For more information on DreamLineTM Shower Enclosures please visit www.

Strona 14

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 3Detailed Diagram of Shower Enclosure Components Diagram A Diagr

Strona 15 - Fig. 22

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 4Shower Enclosure Plan NOTICE: The Guide rail (03) and the Threshold (15) has been precut for the

Strona 16 - Fig. 24

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 5Shower Enclosure Installation 1. Attach the Wall brackets (19) to the Return glass panel (22). Bolte

Strona 17 - Fig. 26

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 6 2. Position the Return panel (22) on desirable distance from the side wall. This distance is marked

Strona 18 - Product Maintenance

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 7 4. Drill the holes in the wall and the floor using Ø 5/16” drill bit and insert the Wall anchors (18)

Strona 19 - WARRANTYSERVICE

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 8 6. According to desirable distance “W” between the wall and the internal side of the Return panel (22

Strona 20

“ ENIGMA” Enclosure Rev. 3 Ver.4 04/2013 98. Your Threshold (15) has been precut for your Shower model opening width: 60” or 72” for shower widt